LAST PRODUCTS VIEWED
RELATED PRODUCT TAGS
Monoclonal Mouse Anti-Human
CD5
Clone 4C7
Reacts with CD5 expressed on B and T cells and may be useful for the identification of B and T-cell malignancies.
This includes B-cell chronic lymphoid leukemia (B-CLL), B-cell small lymphocytic lymphoma (B-SLL), mantle cell lymphoma (MCL) and T-cell lymphoma and leukemia (1-4).
For DakoLink users:
Go to the Autostainer Link Installer section and download the Installer for Code IR082, CD5, Clone 4C7 Protocol Updater. Follow the instructions to complete the update.
Isotype IgG1, kappa
- Formalin
- HIER
- Diaz de Leon E, Alkan S, Huang JC, Hsi ED. Usefulness of an immunohistochemical panel in paraffin-embedded tissues for the differentiation of B-cell non-Hodgkin's lymphomas of small lymphocytes. Mod Pathol 1998;11:1046-51.
- Dorfman DM, Shahsafaei A. Usefulness of a new CD5 antibody for the diagnosis of T-cell and B-cell lymphoproliferative disorders in paraffin sections. Mod Pathol 1997;10:859-63.
- Arber DA, Weiss LM. CD5 a review. Appl Immunohistochem 1995;3:1-22.
- Watson P, Wood KM, Lodge A, McIntosh GG, Milton I, Piggott NH, et al. Monoclonal antibodies recognizing CD5, CD10 and CD23 in formalin-fixed, paraffin-embedded tissue: production assessment of their value in the diagnosis of small B-cell lymphoma. Histopathol 2000;36:145-50.
Mantle cell lymphoma (FFPE) stained with FLEX Anti-CD5, Code IR082/IS082.
Mantle cell lymphoma. The neoplastic cells show a moderate to strong membraneous staining reaction.
Clinical application for IR082/IS082. For identification of B- and T-cell malignancies, including B-cell chronic lymphocytic leukemia/ small lymphocytic lymphoma, mantle cell lymphoma, and T-cell lymphoma and leukemia.
Tonsil. The crowded T cells in the T-zone and the scattered T cells in the germinal center show a moderate to strong staining reaction. In the mantle zone, a weak membranous staining reaction should be seen in scattered B cells.
Recommended control for IR636/IS636. Tonsil.
Disclaimer: Due to variances among color computer monitors, the colors you see on your screen may not be the exact colors of the stain. The image you see should be considered close renditions to the actual stain.
- Concentrated Antibody
for Manual Use - Ready-to-use Antibody
for Autostainer Link Instrument - Ready-to-use Antibody
for Autostainer Plus Instrument
- Excellent specificity
- High lot to lot consistency
- Optimized for immunohistochemistry (IHC) with validated protocols
- Certified manufacturing facilities guarantee full quality control
Monoclonal Mouse Anti-Human CD5, Clone 4C7, is intended for use in immunohistochemistry. The antibody labels CD5-positive cells and may be useful for the identification of B- and T-cell malignancies including B-cell chronic lymphoid leukemia (B-CLL), B-cell small lymphocytic lymphoma (B-SLL), mantle cell lymphoma (MCL) and T-cell lymphoma and leukemia (1-4). The clinical interpretation of any staining or its absence should be complemented by morphological studies using proper controls and should be evaluated within the context of the patient's clinical history and other diagnostic tests by a qualified pathologist.
Clone: 4C7(4). Isotype: IgG1, kappa.
Mouse IgG concentration: See label on vial.
The protein concentration between lots may vary without influencing the optimal dilution. The titer of each individual lot is compared and adjusted to a reference lot to ensure a consistent immunohistochemical staining performance from lot-to-lot.
- Diaz de Leon E, Alkan S, Huang JC, Hsi ED. Usefulness of an immunohistochemical panel in paraffin-embedded tissues for the differentiation of B-cell non-Hodgkin's lymphomas of small lymphocytes. Mod Pathol 1998;11:1046-51.
- Dorfman DM, Shahsafaei A. Usefulness of a new CD5 antibody for the diagnosis of T-cell and B-cell lymphoproliferative disorders in paraffin sections. Mod Pathol 1997;10:859-63.
- Arber DA, Weiss LM. CD5 a review. Appl Immunohistochem 1995;3:1-22.
- Watson P, Wood KM, Lodge A, McIntosh GG, Milton I, Piggott NH, et al. Monoclonal antibodies recognizing CD5, CD10 and CD23 in formalin-fixed, paraffin-embedded tissue: production and assessment of their value in the diagnosis of small B-cell lymphoma. Histopath 2000;36:145-50.
Check Your Price & Order Online
| Product | Size | ![]() | M3641 Culture supernatant
| 0.2 mL Product No. M364129-2 |
|---|---|---|
| 1 mL Product No. M364101-2 |
RECOMMENDED COMPANION PRODUCTS
| Step | Product | Size |
|---|---|---|
| Pre-treatment | EnVision™ FLEX Target Retrieval Solution, High pH (Code K8004) 3-in-1 procedure using PT Link | 3 x 30 mL Product No. K800421-2 |
| Antibody Dilution | Antibody Diluent (Code S0809) Dilute 1:50 | 50 mL Product No. S080981-2 |
| 125 mL Product No. S080983-2 | ||
| Negative Control | Mouse IgG1 (Code X0931) Positive tissue: Tonsil | 1 mL Product No. X093101-2 |
| Visualization System | EnVision™ FLEX (Code K8000/K8010) Use High pH Target Retrieval Solution | 400-600 tests Product No. K800021-2 |
| Counterstain | Hematoxylin (Code K8008/K8018) Non-aqueous, permanent mounting medium is required | 3 x 45 mL, 400-600 tests Product No. K800821-2 |
| Glass Slides | Silanized Slides (Code S3003) Recommended for greater adherence to glass slides | 100 slides Product No. S300330-2 |
- Optimized staining performance of both high- and low-expression structures
- Crisp and clear staining with no background
- Optimal laboratory efficiency with ready-to-use antibodies on Dako Autostainer Link 48
FLEX Monoclonal Mouse Anti-Human CD5, Clone 4C7, Ready-to-Use (Link), is intended for use in immunohistochemistry together with Autostainer Link instruments. The antibody labels CD5-positive cells and may be useful for the identification of B- and T-cell malignancies including B-cell chronic lymphoid leukemia (B CLL), B-cell small lymphocytic lymphoma (B-SLL), mantle cell lymphoma (MCL) and T-cell lymphoma and leukemia (1-4). The clinical interpretation of any staining or its absence should be complemented by morphological studies using proper controls and should be evaluated within the context of the patient's clinical history and other diagnostic tests by a qualified pathologist.
Clone: 4C7 (4). Isotype: IgG1, kappa.
- Diaz de Leon E, Alkan S, Huang JC, Hsi ED. Usefulness of an immunohistochemical panel in paraffin-embedded tissues for the differentiation of B-cell non-Hodgkin's lymphomas of small lymphocytes. Mod Pathol 1998;11:1046-51.
- Dorfman DM, Shahsafaei A. Usefulness of a new CD5 antibody for the diagnosis of T-cell and B-cell lymphoproliferative disorders in paraffin sections. Mod Pathol 1997;10:859-63.
- Arber DA, Weiss LM. CD5 a review. Appl Immunohistochem 1995;3:1-22.
- Watson P, Wood KM, Lodge A, McIntosh GG, Milton I, Piggott NH, et al. Monoclonal antibodies recognizing CD5, CD10 and CD23 in formalin-fixed, paraffin-embedded tissue: production and assessment of their value in the diagnosis of small B-cell lymphoma. Histopath 2000;36:145-50.
Check Your Price & Order Online
| Product | Size | ![]() | IR082 RTU, FLEX
| 60 tests, 12 mL Product No. IR08261-2 |
|---|
RECOMMENDED COMPANION PRODUCTS
| Step | Product | Size |
|---|---|---|
| Pre-treatment | EnVision™ FLEX Target Retrieval Solution, High pH (Code K8004) 3-in-1 procedure using PT Link | 3 x 30 mL Product No. K800421-2 |
| Antibody Dilution | Ready-to-use / Prediluted | |
| Negative Control | FLEX Negative Control, Mouse (Code IR750) Positive tissue: Tonsil | 120 tests, 24 mL Product No. IR75066-2 |
| Visualization System | EnVision™ FLEX (Code K8000) Use High pH Target Retrieval Solution | 400-600 tests Product No. K800021-2 |
| Counterstain | Hematoxylin (Link) (Code K8008) Non-aqueous, permanent mounting medium is required | 3 x 45 mL, 400-600 tests Product No. K800821-2 |
| Glass Slides | Silanized Slides (Code S3003) Recommended for greater adherence Alternative is FLEX IHC Microscope Slides (Code K8020) | 100 slides Product No. S300330-2 |
- Optimized staining performance of both high- and low-expression structures
- Crisp and clear staining with no background
- Optimal laboratory efficiency with ready-to-use antibodies on Dako Autostainer Plus
FLEX Monoclonal Mouse Anti-Human CD5, Clone 4C7, Ready-to-Use (Dako Autostainer/Autostainer Plus), is intended for use in immunohistochemistry together with Dako Autostainer/Autostainer Plus instruments. The antibody labels CD5-positive cells and may be useful for the identification of B- and T-cell malignancies including B-cell chronic lymphoid leukemia (B-CLL), B-cell small lymphocytic lymphoma (B-SLL), mantle cell lymphoma (MCL) and T-cell lymphoma and leukemia (1-4). The clinical interpretation of any staining or its absence should be complemented by morphological studies using proper controls and should be evaluated within the context of the patient's clinical history and other diagnostic tests by a qualified pathologist.
Clone: 4C7 (4). Isotype: IgG1, kappa.
- Diaz de Leon E, Alkan S, Huang JC, Hsi ED. Usefulness of an immunohistochemical panel in paraffin-embedded tissues for the differentiation of B-cell non-Hodgkin's lymphomas of small lymphocytes. Mod Pathol 1998;11:1046-51.
- Dorfman DM, Shahsafaei A. Usefulness of a new CD5 antibody for the diagnosis of T-cell and B-cell lymphoproliferative disorders in paraffin sections. Mod Pathol 1997;10:859-63.
- Arber DA, Weiss LM. CD5 a review. Appl Immunohistochem 1995;3:1-22.
- Watson P, Wood KM, Lodge A, McIntosh GG, Milton I, Piggott NH, et al. Monoclonal antibodies recognizing CD5, CD10 and CD23 in formalin-fixed, paraffin-embedded tissue: production and assessment of their value in the diagnosis of small B-cell lymphoma. Histopath 2000;36:145-50.
Check Your Price & Order Online
| Product | Size | ![]() | IS082 RTU, FLEX
| 30 tests, 6 mL Product No. IS08230-2 |
|---|
RECOMMENDED COMPANION PRODUCTS
| Step | Product | Size |
|---|---|---|
| Pre-treatment | EnVision™ FLEX Target Retrieval Solution, High pH (Code K8004) 3-in-1 procedure using PT Link | 3 x 30 mL Product No. K800421-2 |
| Antibody Dilution | Ready-to-use / Prediluted | |
| Negative Control | FLEX Negative Control, Mouse (Code IS750) Positive tissue: Tonsil | 60 tests, 12 mL Product No. IS75061-2 |
| Visualization System | EnVision™ FLEX (Code K8010) Use High pH Target Retrieval Solution | 400-600 tests Product No. K801021-2 |
| Counterstain | Hematoxylin (Dako Autostainer/Autostainer Plus) (Code K8018) Non-aqueous, permanent mounting medium is required | 10 x 13 mL, 400-600 tests Product No. K801821-2 |
| Glass Slides | Silanized Slides (Code S3003) Recommended for greater adherence Alternative is FLEX IHC Microscope Slides (Code K8020) | 100 slides Product No. S300330-2 |
Synonym(s) for Antigen
T1, Tp67

Denmark
