LAST PRODUCTS VIEWED
RELATED PRODUCT TAGS
Polyclonal Rabbit Anti-Human
Lambda Light Chains
The antigen used for immunization is a pool of human lambda Bence Jones proteins. Therefore, a reagent with a particularly wide specificity for lambda-chains is obtained.
The specificity is directed against surface as well as hidden determinants and has been ascertained by gel precipitation techniques and immunohistochemistry. The antibody labels plasma cells and related lymphoid cells containing lambda light chains, and it is a useful tool for the classification of patients with monoclonal gammopathies and amyloidosis. Additionally, the antibody may be used for distinguishing neoplastic monoclonal proliferation from reactive hyperplasia of B cells.
- Frozen
- Formalin
- Enzyme/HIER
Tonsil (FFPE) stained with FLEX Anti-Lambda Light Chains, Code IR507/IS507.
Tonsil. The B cells and plasma cells show a moderate to strong cytoplasmic staining reaction.
Recommended control for IR507/IS507. Tonsil/Bone marrow.
Plasmacytoma lambda subtype. The plasmacytoma cells show a strong cytoplasmic staining reaction.
Clinical application for IR507/IS507 For identification of plasma cells and lymphoid cells containing lambda light chains, and for classification of lambda light chain restriction for monoclonal gammopathies and amyloidosis.
Tonsil stained with Anti-Lambda Light Chains.
Disclaimer: Due to variances among color computer monitors, the colors you see on your screen may not be the exact colors of the stain. The image you see should be considered close renditions to the actual stain.
- Concentrated Antibody
for Manual Use - Ready-to-use Antibody
for Autostainer Link Instrument - Ready-to-use Antibody
for Autostainer Plus Instrument
- Excellent specificity
- High lot to lot consistency
- Optimized for immunohistochemistry (IHC) with validated protocols
- Certified manufacturing facilities guarantee full quality control
In crossed immunoelectrophoresis, only the lambda precipitation arch appears when using 37.5 µL antibody per cm2 gelarea against 2 µL human plasma. Staining: Coomassie Brilliant Blue.
Protein concentration g/L: See label on vial.
Antibody titre: 200 mg/L (mg of antigen to be added to 1 L of antibody to reach equivalence point).
F/P ratio: E495 nm/E278 nm = 0.65 ± 0.05 corresponding to a molar FITC/protein ratio of 2.5.
Check Your Price & Order Online
| Product | Size | ![]() | A0193 Ig fraction
| 2 mL Product No. A019302-2 | ![]() | F0199 FITC. Ig fraction
| 2 mL Product No. F019902-2 |
|---|
- Optimized staining performance of both high- and low-expression structures
- Crisp and clear staining with no background
- Optimal laboratory efficiency with ready-to-use antibodies on Dako Autostainer Link 48
FLEX Polyclonal Rabbit Anti-Human Lambda Light Chains, Ready-to-Use (Link), is intended for use in immunohistochemistry together with Autostainer Link instruments. This antibody is useful for the identification of plasma cells and related lymphoid cells containing lambda light chains, and it is a useful tool for the classification of patients with monoclonal gammopathies (2) and amyloidosis (3, 4). Additionally, the antibody may be used for distinguishing neoplastic monoclonal proliferation from reactive hyperplasia of B cells (5-7). The clinical interpretation of any staining or its absence should be complemented by morphological studies using proper controls and should be evaluated within the context of the patient's clinical history and other diagnostic tests by a qualified pathologist.
Specificity tests; staining with Coomassie Brilliant Blue:
Double immunodiffusion: No reaction with kappa or gamma chains is seen when using 15 µL of concentrated antibody against 15 µL of kappa IgG.
Crossed immunoelectrophoresis: Only lambda-related precipitates appear when using 12.5 µL concentrated antibody per square cm gel area against 2 µL human plasma or 2 µL of a pool of concentrated urine from patients with tubular proteinuria.
- Peterson LC, Brown BA, Crosson JT, Mladenovic J. Application of the immunoperoxidase technic to bone marrow trephine biopsies in the classification of patients with monoclonal gammopathies. Am J Clin Pathol 1986;85:688-93.
- Strøm EH, Fogazzi GB, Banfi G, Pozzi C, Mihatsch MJ. Light chain deposition disease of the kidney. Morphological aspects in 24 patients. Virchows Arch 1994;425:271-80.
- Jessup E. Antigen retrieval techniques for the demonstration of immunoglobulin light chains in formalin-fixed, paraffin-wax embedded sections. UK NEQAS immunocytochemistry news. Winter 1994/95; Issue 4:12-6.
- Taylor CR, Burns J. The demonstration of plasma cells and other immunoglobulin-containing cells in formalin-fixed, paraffin-embedded tissues using peroxidase-labelled antibody. J Clin Path 1974;27:14-20.
- Harris NL, Poppema S, Data RE. Demonstration of immunoglobulin in malignant lymphomas. Use of an immunoperoxidase technic on frozen sections. Am J Clin Pathol 1982;78:14-21.
- Marshall-Taylor CE, Cartun RW, Mandich D, DiGuiseppe JA. Immunohistochemical detection of immunoglobulin light chain expression in B-cell non-Hodgkin lymphomas using formalin-fixed, paraffin-embedded tissues and a heat-induced epitope retrieval technique. Appl Immunohistochem Mol Morphol 2002;10:258-62.
Check Your Price & Order Online
| Product | Size | ![]() | IR507 RTU, FLEX
| 60 tests, 12 mL Product No. IR50761-2 |
|---|
- Optimized staining performance of both high- and low-expression structures
- Crisp and clear staining with no background
- Optimal laboratory efficiency with ready-to-use antibodies on Dako Autostainer Plus
FLEX Polyclonal Rabbit Anti-Human Lambda Light Chains, Ready-to-Use (Dako Autostainer/Autostainer Plus), is intended for use in immunohistochemistry together with Dako Autostainer/Autostainer Plus instruments. This antibody is useful for the identification of plasma cells and related lymphoid cells containing lambda light chains, and it is a useful tool for the classification of patients with monoclonal gammopathies (2) and amyloidosis (3, 4). Additionally, the antibody may be used for distinguishing neoplastic monoclonal proliferation from reactive hyperplasia of B cells (5-7). The clinical interpretation of any staining or its absence should be complemented by morphological studies using proper controls and should be evaluated within the context of the patient's clinical history and other diagnostic tests by a qualified pathologist.
Specificity tests; staining with Coomassie Brilliant Blue:
Double immunodiffusion: No reaction with kappa or gamma chains is seen when using 15 µL of concentrated antibody against 15 µL of kappa IgG.
Crossed immunoelectrophoresis: Only lambda-related precipitates appear when using 12.5 µL concentrated antibody per square cm gel area against 2 µL human plasma or 2 µL of a pool of concentrated urine from patients with tubular proteinuria.
- Peterson LC, Brown BA, Crosson JT, Mladenovic J. Application of the immunoperoxidase technic to bone marrow trephine biopsies in the classification of patients with monoclonal gammopathies. Am J Clin Pathol 1986;85:688-93.
- Strøm EH, Fogazzi GB, Banfi G, Pozzi C, Mihatsch MJ. Light chain deposition disease of the kidney. Morphological aspects in 24 patients. Virchows Arch 1994;425:271-80.
- Jessup E. Antigen retrieval techniques for the demonstration of immunoglobulin light chains in formalin-fixed, paraffin-wax embedded sections. UK NEQAS immunocytochemistry news. Winter 1994/95; Issue 4:12-6.
- Taylor CR, Burns J. The demonstration of plasma cells and other immunoglobulin-containing cells in formalin-fixed, paraffin-embedded tissues using peroxidase-labelled antibody. J Clin Path 1974;27:14-20.
- Harris NL, Poppema S, Data RE. Demonstration of immunoglobulin in malignant lymphomas. Use of an immunoperoxidase technic on frozen sections. Am J Clin Pathol 1982;78:14-21.
- Marshall-Taylor CE, Cartun RW, Mandich D, DiGuiseppe JA. Immunohistochemical detection of immunoglobulin light chain expression in B-cell non-Hodgkin lymphomas using formalin-fixed, paraffin-embedded tissues and a heat-induced epitope retrieval technique. Appl Immunohistochem Mol Morphol 2002;10:258-62.
Check Your Price & Order Online
| Product | Size | ![]() | IS507 RTU, FLEX
| 30 tests, 6 mL Product No. IS50730-2 |
|---|